PageGate integrates with Zuercher Technologies CAD by monitoring the *.pag files Zuercher outputs using the GetAscii Advanced Polling configuration.
Step 1 — Configure GetAscii
Create:
c:\PageGateData\Ascii\If PageGate is on a separate server, share the directory and provide GetAscii credentials to access it.
Open PG Admin. Go to Interfaces — GetAscii — Settings. Set Polling Directory. Check Enabled. Click Apply. Enable for all.
Step 2 — Configure Advanced Polling
Go to
Advanced Polling — Files. Click
Add. Set:
Recipient: *
From: CAD
File(s): *.pag
Path: [Zuercher *.pag output directory]
File Type: Custom
Click
Apply twice.
Go to
Advanced Polling — Record:
Start Pattern: * | Start Offset: 0
End Pattern: ~ | End Offset: 0
Click
Apply.
Go to
Advanced Polling — Recipient. Select
Dynamic Recipient:
Start Pattern: * | Start Offset: 0
End Pattern: | End Offset: 0
Click
Apply.
Go to
Advanced Polling — Sender. Select
Dynamic Sender:
Start Pattern: FROM: | Start Offset: 1
End Pattern: | End Offset: 0
Click
Apply.
Go to
Advanced Polling — Message. Select
Dynamic Message:
Start Pattern: MSG: | Start Offset: 1
End Pattern: ~ | End Offset: 0
Click
Apply.
Return to Integration Directory