PageGate integrates with Zetron on-site paging solutions using TAP output and can also receive input via the GetTAP module.
Configure PageGate to Output to the Zetron Terminal
Open PageGate Admin. Go to
Connectors — Connector X — Settings.
Any connector can be configured to reference a paging terminal.
Set Serial Port to match the COM/Serial port the terminal is plugged in to. Check Direct Connect. Click Apply.
Right click
Carriers, left click
Add. Specify the following:
Name: Zetron
Protocol: TAP
Baud Rate: [Mirror terminal's setting]
Parity: [Mirror terminal's setting]
Data Bits: [Mirror terminal's setting]
Stop Bits: [Mirror terminal's setting]
Init String: direct
Click Apply. Configure recipients using the pager's cap code or ID in the ID/PIN field.
Configure PageGate to Receive Input (GetTAP)
Open PageGate Admin. Go to Interfaces — GetTAP — Settings.
Set Serial Port, mirror Baud Rate, Parity, Data Bits, Stop Bits from the terminal. Set Init String to: direct
Check Enabled. Click Apply. When prompted, enable for all existing groups and recipients.