PageGate integrates with WaveWare on-site paging solutions using TAP output and can also receive input via the GetTAP module.
Configure PageGate to Output to the WaveWare Terminal
Open the PageGate Admin. Go to
Connectors — Connector X — Settings.
Any connector can be configured to reference a paging terminal.
Set the Serial Port field to match the COM/Serial port the terminal is plugged in to.
Check Direct Connect. Click Apply.
Right click
Carriers, left click
Add. Specify the following:
Name: WaveWare
Protocol: TAP
Baud Rate: [Mirror the paging terminal's setting]
Parity: [Mirror the paging terminal's setting]
Data Bits: [Mirror the paging terminal's setting]
Stop Bits: [Mirror the paging terminal's setting]
Init String: direct
Click Apply. Configure recipients using the pager's cap code or ID in the ID/PIN field.
Configure PageGate to Receive Input from the WaveWare Terminal (GetTAP)
Open the PageGate Admin. Go to Interfaces — GetTAP — Settings.
Set the Serial Port field to match the COM/Serial port the terminal is plugged in to.
Specify Baud Rate, Parity, Data Bits, and Stop Bits to mirror the terminal's settings. Set Init String to: direct
Check Enabled. Click Apply. When prompted, enable for all existing groups and recipients.