Integrate with Existing Applications

Integration with WaveWare Alarm Contact Monitoring

PageGate can be easily integrated with WaveWare's Alarm Contact Monitoring — it can output to the Alarm Contact Monitoring system using the TAP protocol and can also receive input from the monitoring system using the GetTAP receiver module.

Configure PageGate to Output to WaveWare (TAP)

  1. Open the PageGate Admin.
  2. Go to Connectors — Connector X — Settings. Any connector can be configured to reference a paging terminal.
  3. Set the Serial Port field to match the COM/Serial port the terminal is plugged in to.
  4. Check Direct Connect.
  5. Click Apply.
  6. Right click on Carriers, left click on Add. Specify the following:
    Name: WaveWare
    Protocol: TAP
    Baud Rate: Mirror the paging terminal's setting
    Parity: Mirror the paging terminal's setting
    Data Bits: Mirror the paging terminal's setting
    Stop Bits: Mirror the paging terminal's setting
    Init String: direct (type this in the field)
  7. Click Apply. Configure recipients to use the WaveWare carrier. Use the pager's cap code or ID in the ID/Pin field.

Configure PageGate to Receive Input from WaveWare (GetTAP)

  1. Open the PageGate Admin.
  2. Go to Interfaces — GetTAP — Settings.
  3. Set the Serial Port field to match the COM/Serial port the terminal is plugged in to.
  4. Specify the following:
    Baud Rate: Mirror the paging terminal's setting
    Parity: Mirror the paging terminal's setting
    Data Bits: Mirror the paging terminal's setting
    Stop Bits: Mirror the paging terminal's setting
    Init String: direct (type this in the field)
  5. Put a check in Enabled.
  6. Click Apply. When prompted, you do want to enable this for all existing groups and recipients.

Return to Integration Directory

Need help with this integration?

Our support team can walk you through the configuration steps.