PageGate integrates with Spok on-site paging solutions using TAP output and can also receive input via the GetTAP module.
Configure PageGate to Output to the Spok Terminal
Open PageGate Admin. Go to
Connectors — Connector X — Settings.
Any connector can be configured to reference a paging terminal.
Set Serial Port to match the COM/Serial port the terminal is plugged in to. Check Direct Connect. Click Apply.
Right click
Carriers, left click
Add. Specify the following:
Name: SPOK
Protocol: TAP
Baud Rate: [Mirror terminal's setting]
Parity: [Mirror terminal's setting]
Data Bits: [Mirror terminal's setting]
Stop Bits: [Mirror terminal's setting]
Init String: direct
Click Apply. Configure recipients using the pager's cap code or ID in the ID/PIN field.
Configure PageGate to Receive Input from Spok (GetTAP)
Open PageGate Admin. Go to Interfaces — GetTAP — Settings.
Set Serial Port and mirror all port settings from the terminal. Set Init String to: direct
Check Enabled. Click Apply. Enable for all groups and recipients when prompted.
Return to Integration Directory