Integrate with Existing Applications

Integration with NetIQ

NetIQ integrates with PageGate through the GetAscii interface. NetIQ loads a netiqpage.ini file that references PageGate's sendpage32.exe and defines recipients/groups.

Step 1 — Configure GetAscii

  1. Open PG Admin. Go to Interfaces — GetAscii — Settings. Set and note the Polling Directory (e.g. D:\PageGate\Poll\). Check Enabled. Click Apply.

Step 2 — Configure netiqpage.ini

NetIQ creates netiqpage.ini in the Windows root directory. Edit the [system] section to reference PageGate:

[system]
notepage=D:\PageGate\Poll\sendpage32.exe -dir=d:\PageGate\Poll %s %s %s
The path must match the GetAscii Polling Directory. Recipient/group names in PageGate, netiqpage.ini, and NetIQ job actions must all match.

Sample Target Sections:

[ADG]
pageco1=notepage
target1=adg
param1=NetIQ
start_time1=00/00/00 0:06:00
stop_time1=00/00/00 23:00:00

Step 3 — Assign Page-Actions in NetIQ

Assign a "page-action" to the appropriate NetIQ job events. When a monitored event triggers, NetIQ calls sendpage32.exe and PageGate delivers the alert via SMS.

Return to Integration Directory

Need help with this integration?

Our support team can walk you through the configuration steps.