Integrate with Existing Applications

Integration with Lawsoft CAD

PageGate integrates with Lawsoft CAD using the GetAscii Advanced Polling configuration to monitor for text file output from the CAD system.

Step 1 — Configure GetAscii with Advanced Polling

  1. Create: c:\PageGateData\Ascii\. Open PG Admin. Go to Interfaces — GetAscii — Settings. Set Polling Directory. Check Enabled. Click Apply. Enable for all.
  2. Go to Advanced Polling — Files. Click Add:
    Recipient: *
    From: CAD
    File(s): *.txt
    Path: \lawsoft\NotePage (or your Lawsoft CAD data UNC path)
    File Type: Custom
    Click Apply twice.
  3. Go to Advanced Polling — Record: Start Pattern *, End Pattern ~. Click Apply.
  4. Go to Advanced Polling — Recipient: Start Pattern CFS:, Start Offset 4, End Pattern \013. Click Apply.
  5. Go to Advanced Polling — Sender: Select Static Sender, enter CAD. Click Apply.
  6. Go to Advanced Polling — Message: Start Pattern *, End Pattern ~. Click Apply.

Step 2 — Create Groups and Map CFS Codes

  1. In PG Admin, create groups matching your dispatch agencies. Click Apply for each.
  2. Go to Interfaces — GetAscii — Settings — Advanced Polling — Recipient. Click Edit Table → Add. Map CFS codes to PageGate group names:
    Data In: *Fire Department - City*
    Data Out: fire_department_city
  3. Add members to each group via Groups — YourGroup — Members.