Integration with Novar Controls — NotePage, Inc.

Integrate with Existing Applications

Integration with Novar Controls

These are the Advanced Polling options to use with Novar Control Software. From the example message, PageGate will: (1) Look for the Recipient in the first line between "SYSTEM " and "EP", use the Lookup Table to substitute "3001" with a PageGate Recipient name; (2) Use the entire text of the file as the message.

Increase the "Max Characters" setting for each Recipient, as messages may exceed the default 240 character limit.

GetAscii Advanced Polling Settings

Files (Add):

Recipient = *
From = *
Files = *.tmp
Path = [Polling Directory where files are written]
File Type = Custom

Record:

Start Pattern = SYSTEM | Start Offset = 0
End Pattern = ~ | End Offset = 0

Recipient (Dynamic):

Start Pattern = SYSTEM | Start Offset = 7
End Pattern = EP | End Offset = -3
Use Lookup Table = checked
Edit Table: Data In = 3001 | Data Out = [PageGate Recipient name]

Sender (Static):

Sender = Novar Control (or any name)

Message (Dynamic):

Start Pattern = SYSTEM | Start Offset = 0
End Pattern = ~ | End Offset = 0
Use Lookup Table = unchecked

Optional: Add lookup table entries to strip unused lines like "Assign Code:", "Notes:", "Instructions:", etc.

Return to Integration Directory

Need help with this integration?

Our support team can walk you through the configuration steps.