Integration with Mitsubishi's MelEye — NotePage, Inc.

Integrate with Existing Applications

Integration with Mitsubishi's MelEye

PageGate can be easily integrated with Mitsubishi's MelEye by having PageGate's GetASCII API monitor MelEye's fault log file for alerts.

Step 1 — Configure GetAscii Basic Polling

  1. Create: c:\PageGateData\MelEye\
  2. Open PG Admin. Go to Interfaces — GetAscii — Settings. Set Polling Directory to c:\PageGateData\MelEye\. Check Enabled. Click Apply. Enable for all.

Step 2 — Configure Advanced Polling — Files

  1. Go to Interfaces — Settings — GetAscii — Advanced Polling — Files. Click Add.
  2. Specify:
    Recipient: *
    From: MelEye
    File(s): [MelEyeFaultLogName].txt
    Path: [Path to the MelEye Fault Log]
    File Type: Adding
    Click Apply, then Apply again.

Step 3 — Configure Advanced Polling — Record, Recipient, Sender, Message

  1. Record: Start Pattern *, Start Offset 0, End Pattern \013, End Offset 0. Click Apply.
  2. Recipient: If all alerts go to same recipient, select Static Recipient. For dynamic CSV-based routing, use Dynamic Recipient with patterns matching your CSV structure. Click Apply.
    Example Dynamic Start Pattern: \034\044\034*\034\044\034 (Start Offset: -999)
    Example Dynamic End Pattern: \034\044\034 (End Offset: 0)
  3. Sender: Select Static Sender. Enter: MelEye. Click Apply.
  4. Message: Start Pattern *, End Pattern ~. Click Apply.

Step 4 — Clean Up Data with Lookup Table

  1. Check Use Lookup Table. Click Edit Table.
  2. Click Add. Set Data In: *"*, Data Out: [leave blank]. Click Apply.
  3. Click Add. Set Data In: *,*, Data Out: [leave blank]. Click Apply.
Each installation has slightly different settings based on what information you want to read from the MelEye fault log. Contact NotePage support for help if needed.

Return to Integration Directory