Implementing GetAscii for Motorola Spillman

Top  Previous  Next

Without filtering, PageGate will monitor all received information from the API and dispatch any message addressed to an agency code that exists as a recipient or group in PageGate.

 

1)In Windows, create a directory for GetAscii to reference.

Example: c:\PageGateData\ASCII\

2)Run PG Admin.

3)Go to Interfaces - GetAscii - Settings

4)Set 'Polling Directory' to the directory the script resides within. Example: c:\PageGatedata\ASCII\

5)Check 'Enabled' and click Apply.

6)Select 'Yes'

7)Go to Interfaces - GetAscii - Settings - Advanced Polling - Files

8)Click Add

9)Specify the following and click Apply, then click Apply again.

Recipient: *

From: CAD

File(s): *.asc

Path: The path to your script.

Example: C:\PageGateData\sp-pg-ps\

File Type: Custom

 

10) Go to Interfaces - GetAscii - Settings - Advanced Polling - Record

11) Specify the following and click Apply

Start Pattern: *

Start Offset: 0

 

End Pattern: ~

End Offset: 0

 

12) Go to Interfaces - GetAscii - Settings - Advanced Polling - Recipient

13) Select 'Dynamic Recipient', specify the following and click Apply

Start Pattern: <AgencyCode>

Start Offset: 12

 

End Pattern: </AgencyCode>

End Offset: -13

 

14) Go to Interfaces - GetAscii - Settings - Advanced Polling - Sender

15) Select 'Static Sender', enter the name 'CAD' and click Apply

16) Go to Interfaces - GetAscii - Settings - Advanced Polling - Message

17) Specify the following and click Apply

Start Pattern: *

Start Offset: 0

 

End Pattern: ~

End Offset: 0