Integration with Intergraph Computer Aided Dispatch (CAD) — NotePage, Inc.

Integrate with Existing Applications

Integration with Intergraph Computer Aided Dispatch (CAD)

PageGate integrates with Intergraph CAD using either the GetTAP module (for TAP output) or the SNPP listener (for SNPP output).

Option A — GetTAP Integration

  1. Open PG Admin. Go to Interfaces — GetTAP — Settings.
  2. Set Serial Port to match the COM/Serial port Intergraph is plugged in to.
  3. Mirror Intergraph's Baud Rate, Parity, Data Bits, Stop Bits. Set Init String to: direct
  4. Check Enabled. Click Apply. Enable for all groups and recipients.

Option B — SNPP Listener Integration

  1. Create c:\PageGateData\Ascii\. Configure GetAscii pointing to this directory. Enable for all.
  2. Create c:\PageGateData\SNPP\. Move snppserver.exe, pininfo.txt, and snpp.ini from the PageGate installation directory to this folder.
  3. Edit snpp.ini: set OutputFolder=c:\PageGateData\SNPP\ and LogFolder=c:\PageGateData\Logs\. Save.
  4. Edit pininfo.txt to define valid PIN ranges. Example for 10-digit IDs:
    "0000000001","9999999999","PG_Recipient"
  5. Install and start the SNPP Server as a Windows Service:
    snppserver /reinstall
    net start pgsnppserver

Return to Integration Directory