Configure Bryx911 Carriers in PageGate
Open PG Admin. Right click Carriers, select Add.
Add the SNPP carrier:
Name: BryxSNPP
Protocol: SNPP
Host: snpp.bryx911.com
Port: 444
Max Chars: 600
Click
Apply.
Add the SMTP carrier:
Name: BryxSMTP
Protocol: SMTP
Carrier Domain: alert.bryx911.com
Port: [Port required by your SMTP server]
Max Chars: 600
Click
Apply.
Go to Carriers — BryxSMTP — Advanced. Select Deliver through outgoing mail server. Enter SMTP server address, username, password. Click Apply.
Go to Carriers — BryxSNPP — Advanced. Set Failover to BryxSMTP. Click Apply.
Create Recipients
Create recipients tied to the BryxSNPP carrier. In the ID/PIN field, enter the Bryx911-assigned ID (the part before @alert.bryx911.com — PageGate supplies the domain automatically).
Return to Integration Directory